Carbon Dioxide Monitors/Controllers

  • NDIR CO2 Sensor Transmitter nrog BACnet

    NDIR CO2 Sensor Transmitter nrog BACnet

    Qauv: G01-CO2-N Series
    Cov lus tseem ceeb:

    CO2 / Kub / Humidity detection
    RS485 nrog BACnet MS/TP
    Analog linear tso zis
    Phab ntsa mounting
    BACnet CO2 transmitter nrog ntsuas kub thiab txheeb ze av noo, dawb backlit LCD qhia meej nyeem. Nws tuaj yeem muab ib, ob lossis peb 0-10V / 4-20mA tawm tawm los tswj lub qhov cua, BACnet MS / TP kev sib txuas tau koom ua ke rau BAS system. Kev ntsuas ntau tuaj yeem ncav cuag 0-50,000ppm.

  • Carbon Dioxide Transmitter nrog Temp.&RH

    Carbon Dioxide Transmitter nrog Temp.&RH

    Qauv: TGP Series
    Cov lus tseem ceeb:
    CO2 / Kub / Humidity detection
    Sab nraud sensor sojntsuam
    Analog linear outputs

     
    Nws yog tsuas yog siv nyob rau hauv daim ntawv thov ntawm BAS nyob rau hauv lub tsev lag luam rau lub sij hawm saib xyuas cov pa roj carbon dioxide theem, kub thiab txheeb ze av noo. Kuj tseem tsim nyog rau kev siv hauv thaj chaw cog xws li nceb tsev. Lub qhov sab xis ntawm lub plhaub tuaj yeem muab nthuav dav siv. Sab nraud sensor sojntsuam kom tsis txhob muaj cua sov sab hauv ntawm lub transmitter los ntawm kev cuam tshuam kev ntsuas. Dawb backlight LCD tuaj yeem tso saib CO2, Temp thiab RH yog tias xav tau. Nws tuaj yeem muab ib, ob lossis peb 0-10V / 4-20mA tawm tawm thiab Modbus RS485 interface.

  • Sab Hauv Tsev Cua Zoo Saib Xyuas rau CO2 TVOC

    Sab Hauv Tsev Cua Zoo Saib Xyuas rau CO2 TVOC

    Qauv: G01-CO2-B5 Series
    Cov lus tseem ceeb:

    CO2/TVOC/Temperature/Humidity detection
    Phab ntsa mounting / Desktop
    On/off tso zis yeem
    Sab hauv huab cua zoo saib ntawm CO2 ntxiv rau TVOC (sib xyaw gases) thiab ntsuas kub, av noo. Nws muaj tri-xim tsheb zaub rau peb CO2 ntau yam. Lub tswb nrov yog muaj uas tuaj yeem muab tua thaum lub buzzer rings.
    Nws muaj qhov kev xaiv tso tawm rau / tawm los tswj lub tshuab ua pa raws li CO2 lossis TVOC ntsuas. Nws txhawb nqa lub zog: 24VAC / VDC lossis 100 ~ 240VAC, thiab tuaj yeem ntsia tau yooj yim rau ntawm phab ntsa lossis muab tso rau ntawm lub desktop.
    Tag nrho cov tsis tuaj yeem raug preset lossis hloov kho yog tias xav tau.

  • Air Quality Sensor nrog CO2 TVOC

    Air Quality Sensor nrog CO2 TVOC

    Qauv: G01-IAQ Series
    Cov lus tseem ceeb:
    CO2/TVOC/Temperature/Humidity detection
    Phab ntsa mounting
    Analog linear outputs
    CO2 ntxiv rau TVOC transmitter, nrog kub & txheeb ze av noo, kuj ua ke ob qho tib si av noo thiab kub sensors seamlessly nrog lub digital pib them nyiaj. Dawb backlit LCD zaub yog kev xaiv. Nws tuaj yeem muab ob lossis peb 0-10V / 4-20mA tawm tawm thiab Modbus RS485 interface rau cov kev siv sib txawv, uas tau yooj yim ua ke rau hauv lub tsev qhov cua thiab kev lag luam HVAC system.

  • Duct Air Quality CO2 TVOC Transmitter

    Duct Air Quality CO2 TVOC Transmitter

    Qauv: TG9-CO2 + VOC
    Cov lus tseem ceeb:
    CO2/TVOC/Temperature/Humidity detection
    Cov kav dej installation
    Analog linear outputs
    Lub sijhawm tiag tiag tshawb pom cov pa roj carbon dioxide ntxiv rau tvoc (cov roj sib xyaw) ntawm cov pa cua, kuj tuaj yeem xaiv qhov kub thiab txias txheeb ze. Lub ntse sensor sojntsuam nrog cov dej-pov thawj thiab ntxeem tau zaj duab xis tuaj yeem ntsia tau yooj yim rau hauv txhua qhov cua. LCD zaub muaj yog tias xav tau. Nws muab ib tug, ob los yog peb 0-10V / 4-20mA linear outputs. Cov neeg siv kawg tuaj yeem kho CO2 ntau yam uas sib haum nrog cov txiaj ntsig analog ntawm Modbus RS485, kuj tuaj yeem teeb tsa qhov sib txawv ntawm qhov sib txawv liner outputs rau qee qhov sib txawv.